Honeywell RTH111B1024 Non-Programmable Thermostat Overview
The Honeywell RTH111B1024 is a digital, non-programmable thermostat ideal for low-voltage heating and cooling, including millivolt systems and single-stage heat pumps.
Product Description
The Honeywell RTH111B1024 Digital Non-Programmable Thermostat delivers precision comfort control with a user-friendly design. Specifically engineered for low-voltage heating and cooling systems, it seamlessly integrates with milivolt systems and single-stage heat pumps lacking auxiliary heat. This thermostat boasts a large, easily readable digital display, ensuring clear visibility of temperature settings.
Its non-programmable functionality simplifies operation, making it perfect for those seeking straightforward temperature management. The device is designed to remember custom settings, providing consistent comfort without the need for frequent adjustments. With a focus on reliability and ease of use, the RTH111B1024 offers a dependable solution for maintaining a comfortable indoor environment. It’s a practical choice for homes and small businesses alike, offering consistent performance and long-lasting value.
Key Features
The Honeywell RTH111B1024 distinguishes itself through several key features. Its prominent, easy-to-read digital display ensures effortless temperature monitoring at a glance. Being non-programmable, it offers simplified operation, eliminating the complexities of scheduling. The thermostat’s ability to retain custom settings guarantees consistent comfort levels without repeated adjustments.
Designed for compatibility with low-voltage systems, it supports both milivolt setups and single-stage heat pumps (without auxiliary heat). This versatility makes it a suitable upgrade for a wide range of existing heating and cooling configurations. Furthermore, the RTH111B1024 is backed by a 1-year limited warranty, providing peace of mind and demonstrating Resideo’s commitment to quality and customer satisfaction. It’s a reliable and straightforward solution for maintaining a comfortable home environment.
System Compatibility
The Honeywell RTH111B1024 Digital Non-Programmable Thermostat exhibits broad system compatibility, making it a versatile choice for many homes. Primarily, it’s engineered for low-voltage heating and cooling systems. This includes traditional forced-air furnaces and central air conditioning units operating on standard 24V control circuits.
Specifically, the thermostat is well-suited for milivolt systems, commonly found in fireplaces and some wall heaters. Crucially, it also supports single-stage heat pumps, but without auxiliary or emergency heat capabilities. It’s important to note that this model isn’t designed for high-voltage systems or those requiring complex programming features. Confirming your system’s voltage and stage configuration before installation is vital to ensure proper operation and avoid potential compatibility issues.

Installation Guide
Proper installation involves identifying your system type, carefully following wiring diagrams, installing batteries correctly, and verifying fan operation for optimal performance.
Identify System Type
Before beginning the installation of your Honeywell RTH111B1024 thermostat, accurately identifying your existing heating and cooling system is crucial for correct wiring and operation. This thermostat is specifically designed for low-voltage systems, encompassing both millivolt systems and single-stage heat pumps without auxiliary heat.
Millivolt systems are commonly found in fireplaces or wall heaters, utilizing a low-voltage power source. Single-stage heat pumps, conversely, provide both heating and cooling but lack a secondary, auxiliary heating element. Incorrectly wiring the thermostat to a system it isn’t designed for can lead to malfunction or damage. Carefully review your existing system’s wiring and documentation to determine its type before proceeding with the installation process. If unsure, consult a qualified HVAC technician.
Alternate Wiring Configurations
While the standard wiring diagram for the Honeywell RTH111B1024 covers most common low-voltage systems, some installations may require alternate configurations. These variations often arise with specific heat pump setups or older heating systems. Always prioritize safety by disconnecting power before attempting any wiring changes.
If your system doesn’t perfectly match the standard wiring, carefully examine the existing wiring and compare it to the alternate wiring diagrams provided in the thermostat’s documentation. Pay close attention to the terminal designations (R, W, Y, G, C). Incorrect wiring can cause the system to operate improperly or even become damaged. If you encounter a configuration not covered in the manual, or feel uncomfortable making the connections, it’s best to consult a qualified HVAC professional for assistance.
Install Batteries
The Honeywell RTH111B1024 thermostat requires two AA alkaline batteries to operate, even when hardwired with a “C” wire. This ensures continued functionality during power outages. To install the batteries, locate the battery compartment, typically on the back or side of the thermostat unit. Open the compartment cover – it may require a small screwdriver or simply a firm press.
Insert the batteries, ensuring correct polarity (+ and -) as indicated inside the compartment. Incorrect battery installation will prevent the thermostat from powering on. Once the batteries are securely in place, close the compartment cover. The thermostat display should illuminate, confirming successful battery installation. Replace batteries annually, or when the low battery indicator appears on the display, to maintain reliable operation.

System-Specific Instructions
The RTH111B1024 supports millivolt systems and single-stage heat pumps without auxiliary heat; specific wiring and setup will vary based on your heating/cooling setup.
For Millivolt Systems
Millivolt systems, commonly found in fireplaces or older heating setups, require careful wiring with the Honeywell RTH111B1024. Typically, you’ll connect the thermostat wires to the millivolt power supply, ensuring correct polarity. The ‘R’ terminal connects to the positive voltage, while ‘W’ controls the heating valve.
It’s crucial to verify the millivolt output of your system before connecting the thermostat; incorrect voltage can damage the unit. Double-check the wiring diagram specific to your fireplace or heater, as configurations can differ. A common setup involves ‘R’ for power, ‘W’ for heat, and ‘C’ for common (if applicable).
Always turn off power to the system before making any connections. If unsure, consult a qualified HVAC technician to ensure safe and proper installation for optimal performance and safety.
For Single-Stage Heat Pumps (Without Auxiliary Heat)
Installing the RTH111B1024 with a single-stage heat pump (without auxiliary heat) requires specific wiring. Connect the ‘R’ terminal to the heat pump’s power source, ‘Y’ to the compressor, and ‘W’ to the reversing valve. Ensure the ‘O’ or ‘B’ terminal is correctly identified for reversing valve control – consult your heat pump’s documentation.
Proper wiring is vital for correct heating and cooling operation. Incorrect connections can lead to inefficient performance or system damage. Verify that the heat pump is configured for the correct operation mode (heating or cooling) before proceeding.
Always disconnect power before wiring. If you are unfamiliar with heat pump wiring, seek assistance from a qualified HVAC professional to guarantee a safe and functional installation.
Advanced Installation Considerations
When installing the RTH111B1024, consider potential wiring complexities. Some systems may require a ‘C’ (common) wire for consistent power, though the thermostat functions without it. If a ‘C’ wire isn’t present, a common wire adapter might be necessary – these are sold separately.
Pay close attention to wire gauge and connections; loose wires can cause intermittent operation. Ensure all connections are secure and insulated. For optimal performance, locate the thermostat away from direct sunlight, drafts, and heat-generating appliances.
If your system utilizes a high-efficiency furnace, verify compatibility. Consult a qualified HVAC technician if you encounter any uncertainties during the installation process to avoid potential issues.

Thermostat Controls & Operation
The RTH111B1024 features a large, easy-to-read digital display and simple controls for adjusting the temperature to your desired comfort level.
Display Screen Explanation
The Honeywell RTH111B1024 thermostat utilizes a clear, digital display to present essential information at a glance. The primary area showcases the current room temperature, prominently displayed in a large font for easy readability. Below this, the set temperature is indicated, representing the desired heating or cooling level.
Additionally, the display incorporates indicator icons. A flame icon illuminates when the heating system is actively engaged, while a snowflake icon signifies cooling operation. The fan icon indicates whether the fan is set to ‘Auto’ or ‘On’. A battery icon will appear to signal low battery levels, prompting a replacement. Understanding these icons and temperature readings allows for quick and efficient control of your home’s climate.
Temperature Adjustment
Adjusting the temperature on your Honeywell RTH111B1024 thermostat is straightforward. Utilize the Up and Down temperature control buttons, conveniently located on the thermostat’s faceplate. Each press of these buttons will alter the set temperature by one degree Fahrenheit. Observe the display screen to confirm the desired temperature is selected.
The thermostat doesn’t offer programmable schedules; adjustments are made manually as needed. To increase the temperature, press the Up button. To decrease it, press the Down button. The system will then automatically activate to reach and maintain the newly set temperature. Remember that the displayed temperature is the target, and it may take time for the room to reach that level.

Maintenance
Regular maintenance for the RTH111B1024 includes annual battery replacement and occasional cleaning of the display screen with a soft, dry cloth.
Battery Replacement Procedure
To replace the batteries in your Honeywell RTH111B1024 thermostat, begin by gently removing the thermostat cover. Typically, this involves lifting or sliding the cover upwards. Once the cover is removed, you’ll locate the battery compartment. This compartment usually houses two AA batteries. Carefully remove the old batteries, noting the correct polarity – positive (+) and negative (-).
Insert fresh AA batteries, ensuring they are aligned with the correct polarity markings within the compartment. Incorrect battery installation can prevent the thermostat from functioning properly. After inserting the new batteries, reattach the thermostat cover, ensuring it clicks securely into place. The thermostat should now power on and display the current temperature. It’s recommended to replace batteries annually or when the low battery indicator appears on the display screen to maintain consistent operation.
Cleaning Instructions
Maintaining a clean Honeywell RTH111B1024 thermostat ensures optimal performance and longevity. Before cleaning, always turn off the power to the thermostat at the circuit breaker to prevent electrical shock. Begin by removing the thermostat cover – gently lift or slide it off, depending on the model. Use a soft, dry cloth to wipe down the exterior of the thermostat, removing any dust or dirt.
For stubborn marks, lightly dampen the cloth with water, but avoid using harsh chemicals, abrasive cleaners, or excessive moisture. Do not spray any liquids directly onto the thermostat. Carefully wipe the display screen with a clean, dry cloth. Once cleaned, reattach the thermostat cover, ensuring it’s securely in place. Regular cleaning, approximately every few months, will help keep your thermostat looking and functioning its best.

Troubleshooting
If your RTH111B1024 isn’t functioning correctly, check battery installation, wiring connections, and system compatibility before seeking professional assistance for repairs.
Common Issues & Solutions
Display is Blank: The most frequent cause is depleted batteries. Replace with fresh alkaline batteries, ensuring correct polarity. If the display remains blank, verify the wiring connections to the thermostat, specifically the power wire (typically labeled ‘C’). A loose connection can prevent power from reaching the unit.
Incorrect Temperature Readings: Ensure the thermostat isn’t exposed to direct sunlight, drafts, or heat sources, as these can influence accuracy. If the issue persists, recalibrate the thermostat if your system allows, or consider relocating it to a more representative location within the space.
System Doesn’t Respond: Double-check the system type setting within the thermostat’s configuration. Incorrect settings can prevent proper operation. Also, inspect the wiring for any breaks or shorts. For heat pump systems, confirm the reversing valve wire is correctly connected.
Thermostat Cycles Rapidly: This often indicates a wiring issue or a problem with the heating/cooling system itself. Verify the wiring is secure and matches your system’s configuration. If the problem continues, consult a qualified HVAC technician.
Electrical Ratings
The Honeywell RTH111B1024 thermostat is designed for low-voltage applications, specifically 24 VAC (Volts Alternating Current). It’s crucial to verify your heating and cooling system operates within this voltage range before installation to prevent damage to the thermostat or the system itself. The thermostat’s power requirements are minimal, primarily drawing power from batteries when a ‘C’ wire isn’t present.
The thermostat supports a maximum load of 0.5 amps (at 24 VAC) for heating and cooling circuits. Exceeding this limit can lead to malfunction or failure. It’s compatible with standard heating, cooling, and heat pump systems, but not designed for line voltage (120/240 VAC) applications. Always disconnect power to the system before performing any wiring changes.
The RTH111B1024 is intended for indoor use only and should not be exposed to moisture or extreme temperatures. Proper electrical grounding is essential for safe operation. Refer to a qualified electrician if you are unsure about any electrical aspects of the installation.

Warranty Information
Resideo provides a one-year limited warranty covering defects in materials and workmanship from the original purchase date, excluding batteries.
1-Year Limited Warranty Details
Resideo warrants the RTH111B1024 thermostat, excluding the battery, against defects in workmanship or materials for one year from the original purchase date. This warranty applies under normal use and service conditions. Should the product prove defective during the warranty period, Resideo will, at its option, either repair or replace the defective unit.
This warranty does not cover damage resulting from misuse, abuse, improper installation, or unauthorized modifications. The original purchaser must provide proof of purchase to validate the warranty claim. This warranty is non-transferable and applies only to the original retail purchaser. Resideo’s liability is limited to the repair or replacement of the product, and does not include any incidental or consequential damages.
Warranty Claim Process
To initiate a warranty claim for your RTH111B1024 thermostat, first gather your original proof of purchase, including the date of purchase and retailer information. Contact Resideo Customer Assistance (see contact details elsewhere in this manual) to obtain a Return Merchandise Authorization (RMA) number. Package the defective thermostat securely, including all original components, and clearly mark the RMA number on the outside of the package.
Ship the package, prepaid, to the address provided by Resideo Customer Assistance. Resideo will inspect the returned product and, if the defect is covered under warranty, will repair or replace it. Allow several weeks for processing and return shipping. This process ensures efficient handling of all warranty requests.

Customer Assistance
For support regarding your RTH111B1024 thermostat, explore online resources or directly contact Resideo for prompt assistance with any questions.
Contact Information
If you require direct assistance with your Honeywell RTH111B1024 Non-Programmable Thermostat, Resideo provides several avenues for support. While a dedicated phone number specifically for this model isn’t prominently displayed, customers are directed to Resideo’s general customer care channels. You can typically find contact details, including phone numbers and email addresses, on the Resideo website (resideo.com).
Be prepared to have your thermostat’s model number (RTH111B1024) readily available when contacting support, as this will help them quickly address your specific inquiry. Additionally, referencing your purchase date may be helpful, especially if you are inquiring about warranty coverage. Resideo’s support team can assist with troubleshooting, installation questions, and warranty claims related to your thermostat.
Online Resources
Resideo’s website (resideo.com) serves as a central hub for online resources pertaining to the RTH111B1024 Non-Programmable Thermostat. You can access a digital version of the installation guide, troubleshooting FAQs, and potentially, instructional videos demonstrating setup and operation. Many retailers that sell the thermostat, such as Home Depot and Amazon, also host downloadable manuals and customer reviews on their product pages.
Furthermore, numerous online forums and DIY home improvement websites feature discussions and user-submitted solutions related to Honeywell thermostats. Searching for “RTH111B1024 troubleshooting” or “RTH111B1024 installation” will yield a wealth of community-driven support. YouTube also contains helpful video tutorials created by both Resideo and independent users demonstrating installation and basic operation.