Little Giant Condensate Pump Manual: A Comprehensive Guide

This manual details Little Giant condensate pumps, covering installation, operation, maintenance, and troubleshooting for models like the 550522 and EC-1-DV series.

Understanding Little Giant Condensate Pumps

Little Giant condensate pumps are engineered for reliable removal of water generated by cooling, refrigeration, and dehumidification systems. These pumps, including models like the 1-ABS (550522) and 3-ABS (551320) shallow pan pumps, automatically collect and discharge condensate, preventing overflow and potential water damage.

The Little Giant product line offers diverse solutions, from compact units with tanks to miniature systems ideal for split air conditioning or refrigeration units. They are designed for automatic operation, requiring minimal intervention once installed. The RIM-U model is specifically tailored for commercial ice machines, ensuring compatibility and efficient water removal.

Understanding the specific model and its capabilities is crucial for proper application and maintenance, ensuring long-term performance and preventing costly repairs. These pumps are built for both commercial and industrial use.

What is a Condensate Pump and Why Use One?

A condensate pump is a specialized pump designed to remove water that condenses from cooling and dehumidifying processes. This water, known as condensate, is a byproduct of air conditioning, refrigeration, and even high-efficiency furnaces. Without a pump, this condensate can accumulate, leading to water damage, mold growth, and operational inefficiencies.

Using a condensate pump, like those offered by Little Giant, is essential when gravity drainage isn’t possible. This often occurs in basements, interior locations, or when the condensate drain line needs to travel uphill.

Little Giant pumps provide a reliable, automatic solution, preventing overflows and protecting property. They are crucial for maintaining the functionality and longevity of HVAC and refrigeration systems, ensuring consistent performance and peace of mind.

Little Giant Pump Company History & Overview

The Little Giant Pump Company boasts a rich history, originating as the Little Giant Vaporizer Company in 1940, organized under Oklahoma laws. Initially focused on vaporizers, the company quickly expanded its expertise into pump manufacturing, becoming a trusted name in fluid handling solutions.

Over the decades, Little Giant has become renowned for its durable, reliable pumps serving diverse industries, including HVAC, refrigeration, and commercial applications. They offer a comprehensive range of pumps – sump, chemical, condensate, effluent, sewage, and utility – catering to both commercial and industrial needs.

Today, Little Giant is a brand of Franklin Electric Co., Inc., continuing a legacy of innovation and quality. Their commitment to solving condensate and drain pumping challenges remains steadfast, providing efficient and dependable solutions for customers worldwide.

Popular Little Giant Condensate Pump Models

Little Giant offers a diverse range of condensate pumps tailored to various applications. The Model 550522 (1-ABS) is a shallow pan condensate pump, ideal for standard HVAC systems, featuring a 115VAC power supply and 10 ft shut-off. For higher demands, the Model 551320 (3-ABS) provides a robust solution with 5.17 GPM flow rate and 11.2 ft shut-off.

The EC-1-DV Series represents a miniature condensate removal pump, perfect for split air conditioning units and refrigeration systems, boasting multi-voltage operation for versatile installation. Specifically, the RIM-U model is designed for commercial ice machines, offering compatibility with original equipment and including multiple adapters.

These models demonstrate Little Giant’s commitment to providing reliable and efficient condensate removal solutions, adaptable to a wide spectrum of needs.

Model 550522 (1-ABS Shallow Pan Condensate Pump)

The Little Giant 550522 is a 1-ABS shallow pan condensate pump designed for reliable removal of condensate from air conditioning, refrigeration, and dehumidification systems. Operating on a 115VAC power supply, this model features a compact design for easy integration into tight spaces.

It boasts a 10 ft maximum shut-off head, ensuring efficient water removal. This pump is frequently used in residential and light commercial applications where condensate volumes are moderate. It’s designed to be fitted with discharge adaptors and check valves for safe and effective condensate discharge.

The 550522 is known for its durable construction and automatic operation, providing a dependable solution for condensate management.

Model 551320 (3-ABS Shallow Pan Condensate Pump)

The Little Giant 551320 is a robust 3-ABS shallow pan condensate pump, engineered for higher condensate volume applications compared to the 550522. This model operates on 115VAC and delivers a flow rate of 5.17 GPM (gallons per minute), making it suitable for commercial settings.

With a maximum shut-off head of 11.2 ft, the 551320 effectively handles condensate removal from larger HVAC systems and refrigeration units. Like other Little Giant pumps, it’s compatible with discharge adaptors and check valves for secure drainage.

Its durable ABS construction ensures longevity, while automatic operation minimizes maintenance needs. The 551320 provides a reliable and efficient solution for demanding condensate pumping requirements.

EC-1-DV Series Mini Condensate Removal Pump

The Little Giant EC-1-DV Series represents a compact and versatile solution for mini-split air conditioning and refrigeration condensate removal. Notably, this pump offers multi-voltage operation, simplifying installation across various electrical systems.

Designed for discreet placement, the EC-1-DV boasts a small footprint while delivering reliable performance. It’s ideal for applications where space is limited, such as within air handling units or under equipment.

Franklin Electric, the parent company, highlights its efficiency and ease of use. The pump automatically activates and deactivates based on condensate levels, requiring minimal intervention. Its robust design ensures long-term dependability in demanding environments.

Installation Guide

Proper installation ensures optimal performance and longevity of your Little Giant condensate pump; follow safety precautions and use the correct tools.

Safety Precautions Before Installation

Before commencing installation, always disconnect the electrical power supply at the circuit breaker or fuse box to prevent electrical shock. Ensure the pump is properly grounded according to local electrical codes. Inspect the pump and all components for any shipping damage; do not install a damaged pump.

Exercise caution when handling the pump, as some parts may have sharp edges. Wear appropriate personal protective equipment, including safety glasses and gloves. Verify that the voltage supplied matches the pump’s voltage requirement, typically 115VAC.

Installation should be performed by a qualified technician familiar with electrical and plumbing systems. Avoid installing the pump in areas prone to freezing, as this can damage the unit. Never operate the pump without the tank properly secured, and ensure adequate ventilation around the pump to prevent overheating. Always adhere to all applicable local and national codes.

Required Tools and Materials

For a successful Little Giant condensate pump installation, gather these essential tools and materials: A screwdriver set (Phillips and flathead), adjustable wrench, pipe cutter or hacksaw, Teflon tape, electrical connectors (wire nuts), wire stripper/crimper, and a multimeter for voltage verification.

You’ll also need discharge tubing compatible with the pump’s outlet size, check valve to prevent backflow, and appropriate fittings for connecting to the drain line. A level is crucial for ensuring proper pump positioning.

Depending on the installation, you might require PVC cement and primer for joining PVC pipes. Safety glasses and gloves are recommended for personal protection. Finally, ensure you have access to the pump’s wiring diagram and this manual for reference throughout the process.

Step-by-Step Installation Process

Begin by mounting the Little Giant condensate pump on a stable, level surface near the condensate source. Next, carefully connect the discharge adaptor and check valve to the pump outlet, ensuring a tight seal using Teflon tape. Route the discharge tubing to a suitable drain, avoiding kinks or sharp bends.

Before wiring, ALWAYS disconnect power at the breaker. Connect the pump’s power cord to the appropriate voltage supply, following the wiring diagram. Verify correct polarity with a multimeter; Secure all wiring connections with wire nuts.

Finally, test the pump by slowly adding water to the collection tank. Observe for leaks and confirm proper pump operation.

Connecting Discharge Adaptors and Check Valves

Properly connecting discharge adaptors and check valves is crucial for efficient condensate removal. Begin by selecting the correct adaptor size to match your discharge tubing. Apply Teflon tape to the male threads of both the pump outlet and the adaptor to ensure a watertight seal.

Hand-tighten the adaptor, then use a wrench for a quarter-turn to secure it firmly. Always install a check valve in the discharge line to prevent backflow of condensate. Ensure the check valve’s flow direction arrow points away from the pump.

Securely clamp the discharge tubing to the adaptor and check valve to prevent accidental disconnection. Regularly inspect these connections for leaks or damage.

Wiring and Electrical Connections

Before making any electrical connections, disconnect power at the circuit breaker to prevent electric shock. Little Giant pumps typically operate on 115VAC. Verify your pump’s voltage requirement before wiring. Use appropriately sized wiring, following local electrical codes.

Connect the pump’s power cord to a grounded outlet. Never cut or bypass the grounding pin. If hardwiring, connect the black (hot) wire to the hot terminal, white (neutral) wire to the neutral terminal, and green (ground) wire to the ground terminal.

Ensure all connections are secure and protected within an approved electrical enclosure. Double-check wiring before restoring power.

Operation and Maintenance

Regular maintenance ensures optimal performance and extends the life of your Little Giant condensate pump, including cleaning and component inspections.

Understanding Pump Operation

Little Giant condensate pumps are designed for automatic operation, efficiently removing water generated by HVAC systems, ice machines, and refrigeration units. These pumps utilize a float switch mechanism; as condensate levels rise within the tank, the float activates, initiating the pump. Once the water level decreases, the float drops, automatically shutting off the pump.

The pumps are engineered to handle continuous duty cycles, meaning they can operate frequently without overheating. Different models, like the EC-1-DV, offer multi-voltage operation for increased flexibility. Proper operation relies on correct installation, including secure discharge lines and appropriate electrical connections. Understanding this cycle ensures reliable condensate removal and prevents potential water damage. Regular checks confirm the float switch moves freely and the pump starts/stops as expected.

Routine Maintenance Procedures

Consistent maintenance extends the lifespan and efficiency of your Little Giant condensate pump. Regularly, typically quarterly, inspect the pump and tank for debris accumulation. Cleaning the Pump and Tank involves disconnecting power, removing the tank, and flushing it with clean water to eliminate sediment and algae. Check the intake screen for obstructions and clear as needed.

Inspecting and Replacing Components includes verifying the float switch operates smoothly and the discharge line remains unobstructed. Periodically examine the pump’s exterior for cracks or leaks. If the pump exhibits reduced performance or unusual noises, consider replacing worn components. Following these procedures ensures optimal operation and prevents costly repairs, safeguarding against water damage.

Cleaning the Pump and Tank

Regular cleaning is crucial for maintaining optimal performance. Begin by disconnecting the power supply to prevent electrical shock. Carefully remove the pump’s tank, ensuring no residual water spills. Inspect the tank’s interior for sediment, algae, or debris buildup; Flush the tank thoroughly with clean water, using a mild detergent if necessary, to dislodge any contaminants.

Pay close attention to the intake screen, removing any obstructions that could impede water flow. Rinse the pump housing externally to remove dust or grime. Reassemble the tank securely, verifying a watertight seal. A clean pump and tank ensure efficient condensate removal and prolong the pump’s operational life, preventing potential malfunctions.

Inspecting and Replacing Components

Periodic inspection of key components is vital for reliable operation. Regularly check the discharge adaptor and check valve for cracks or wear, replacing them if damaged to prevent leaks. Examine the pump’s wiring for fraying or corrosion, addressing any issues promptly to avoid electrical hazards. Inspect the impeller for debris or damage, cleaning or replacing it as needed to maintain pumping efficiency.

Monitor the pump’s float switch for smooth movement and proper activation. If the switch is stuck or malfunctioning, replacement is recommended. When replacing parts, always use genuine Little Giant components to ensure compatibility and performance. Proper component maintenance extends the pump’s lifespan and minimizes downtime.

Troubleshooting Common Issues

This section provides solutions for typical problems like pump failure to start, inadequate pumping, excessive noise, and water leaks around the unit.

Pump Not Starting

If your Little Giant condensate pump fails to start, begin by verifying the power supply. Ensure the pump is correctly plugged into a functioning electrical outlet and that the circuit breaker hasn’t tripped. Check the pump’s wiring connections, confirming they are secure and free from corrosion. A faulty float switch is a common culprit; inspect it for obstructions or damage, ensuring it moves freely with the condensate level.

Additionally, examine the pump’s thermal overload protector. If it has tripped, allow the pump to cool down before attempting to restart it. A locked rotor condition, caused by debris within the pump housing, can also prevent startup. Disconnect power and carefully inspect the impeller area for obstructions. Finally, confirm the pump’s voltage matches the supply voltage – incorrect voltage will prevent operation.

Pump Running But Not Pumping

If the Little Giant condensate pump is running but failing to move water, the issue likely lies within the pump’s internal components or discharge line. First, inspect the pump’s intake for obstructions – sediment, algae, or debris can block water flow. Carefully check the impeller for damage or blockage; a cracked or obstructed impeller significantly reduces pumping capacity.

Next, examine the discharge line and check valve. A clogged discharge line or a faulty check valve preventing proper flow are common causes. Ensure the check valve is installed correctly, allowing water to flow out of the pump. Verify there are no kinks or restrictions in the discharge tubing. Air trapped within the pump housing can also hinder performance; try priming the pump according to the manufacturer’s instructions.

Noisy Pump Operation

Unusual noises emanating from your Little Giant condensate pump often indicate mechanical issues or improper installation. A common cause is vibration – ensure the pump is securely mounted on a stable surface, utilizing rubber isolation pads to dampen vibrations. Check for loose components; tighten any screws or fittings that appear insecure.

Internal pump noise can signal impeller problems. Debris lodged within the impeller housing or a worn-out impeller can create rattling or grinding sounds. Inspect and clean the impeller, replacing it if damaged. A failing motor bearing can also produce a high-pitched whine or grinding noise, necessitating pump replacement. Finally, confirm the discharge line isn’t causing noise through water hammer; proper support and a check valve can mitigate this.

Water Leaks Around the Pump

Discovering water leaks around your Little Giant condensate pump requires immediate attention to prevent water damage. First, inspect all connections – discharge adaptors, check valves, and the pump body itself – ensuring they are tightly secured. Verify the integrity of the discharge tubing, checking for cracks or loose fittings. A faulty pump seal is a frequent culprit; if the seal is damaged, it must be replaced.

Leaks from the pump’s tank often indicate a crack or compromised seam. Carefully examine the tank for any visible damage. If a crack is present, the entire pump unit likely needs replacement. Ensure the pump is level; an unlevel pump can strain seals and cause leaks. Finally, confirm the condensate drain line is clear and not backing up, potentially forcing water to escape around the pump.

Specific Applications

Little Giant pumps excel in diverse settings, including commercial ice machines (RIM-U), HVAC condensation removal, and refrigeration units, offering reliable fluid management solutions.

Use with Commercial Ice Machines (RIM-U Model)

The Little Giant RIM-U condensate pump is specifically engineered as a direct replacement for original equipment water pumps found in numerous commercial ice machines. This model distinguishes itself through its versatile design, incorporating multiple adapters and impellers to ensure compatibility with a broad spectrum of ice machine brands and configurations.

Designed for handling potable water, the RIM-U offers a robust and reliable solution for condensate removal. Its construction prioritizes durability and resistance to the demands of continuous operation within commercial environments. Installation is streamlined thanks to the included accessories, simplifying the replacement process and minimizing downtime.

Proper selection of the correct adapter and impeller is crucial for optimal performance. Refer to the RIM-U installation guide for detailed instructions and compatibility charts to guarantee a secure and efficient fit within your specific ice machine model. Regular maintenance, as outlined in this manual, will further extend the pump’s lifespan and ensure consistent operation.

HVAC Condensation Removal

Little Giant condensate pumps are widely utilized for the automatic collection and removal of condensation generated by HVAC systems, including air conditioners, furnaces, and dehumidifiers. These pumps efficiently manage condensate produced during the cooling process, preventing water damage and maintaining optimal system performance.

Various Little Giant models, such as the 550522 and 551320, are ideally suited for HVAC applications due to their compact size, reliable operation, and ability to handle varying condensate volumes. Proper installation, including secure discharge line routing and appropriate electrical connections, is essential for trouble-free operation.

Regular maintenance, including periodic cleaning of the pump tank and inspection of components, is crucial to prevent clogs and ensure continued efficiency. Addressing condensate drainage issues promptly safeguards against potential water damage and extends the lifespan of both the pump and the HVAC system.

Refrigeration Unit Applications

Little Giant condensate pumps offer effective solutions for condensate removal in diverse refrigeration unit setups, including walk-in coolers, display cases, and commercial refrigeration systems. These pumps efficiently manage condensate generated during the refrigeration cycle, preventing water accumulation and maintaining hygienic conditions.

The miniature pumping systems, like the EC-1-DV series, are particularly well-suited for split units in refrigeration applications due to their compact design and reliable performance. Proper selection of the pump model, considering condensate volume and lift requirements, is crucial for optimal operation.

Regular inspection and cleaning of the pump and tank are essential to prevent blockages and ensure consistent condensate removal. Utilizing appropriate discharge adaptors and check valves guarantees safe and efficient drainage, safeguarding refrigeration equipment and preventing potential issues.